Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Connector Type: | CCS1, CCS2, CHAdeMO, GB/T, CCS2 |
| Installation: | Floor Type, Floor Type |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency





Guangzhou Max Power New Energy Technology Co., Ltd. is a high-tech company which has been invested by the fund supported by Jiangxi provincial government. It focuses on the R&D for the core parts such as on/off board charger & DCDC for new energy vehicle(EV, PHEV etc.). The core team members have rich working experience overseas education. The products we developed (OFBC,OBC & DCDC) have excellent performance and dominant position in the market.7kw portable charger
|
MODEL
|
60KW
|
120KW
|
150KW
|
|
INPUT
|
|||
|
Nominal Input Voltage
|
380 VAC ± 15%
|
||
|
Acceptable Input Voltage Range
|
3-phase, 3ph + N + PE
|
||
|
Working Voltage Range
|
50 - 60 Hz
|
||
|
Maximum Input Current
|
118 A
|
225A
|
278A
|
|
Frequency Range
|
<= 5%
|
||
|
Input Power Factor
|
> 0.99 @nominal voltage (100% load)
|
||
|
OUTPUT
|
|||
|
Output Current Range (based on 2-output)
|
2 ~ 100 A
|
2 ~ 200 A
|
2 ~ 250 A
|
|
Output Voltage Range
|
200~750VDC (600~750VDC in constant power mode)
|
||
|
Power Module
|
30kW x 2 pcs
|
30kW x 4 pcs
|
30kW x5 pcs
|
|
Efficiency
|
> 94%
|
||
|
Module Output Current Unbalancce
|
< 5%
|
||
|
Module Output Voltage Ripple
|
< 0.5
|
||
|
Module Output Voltage Precision
|
< 0.5%
|
||
|
MModule Output Current Precision
|
< 1%
|
||
|
Connector Single Mode (max.)
|
CCS2 (60kW) ChAdeMO (50kW)
|
CCS2 (120kW)
ChAdeMO (50kW)
|
CCS2 (150kW) ChAdeMO (50kW)
|
|
Connector Double Mode (max.)
|
CCS2 (30kW) ChAdeMO (50kW)
|
CCS2 (60kW)
ChAdeMO (50kW)
|
CCS2 (90kW)
ChAdeMO (50kW)
|
|
Power Distribution
|
Single plug mode / Average output mode
|
||
|
PROTECTION
|
|||
|
Charger Safety Protection
|
Over/Under voltage, overload, output power limit function, short circuit, anti-access, earth leakage, lightning and overheat
protection |
||
|
Interface Safety Portection
|
Circuit discharge function, insulation monitoring device (IMD) and battery reverse parity protection
|
||
|
USER INTERFACE
|
|||
|
Status Indiators
|
Power on, charging and fault
|
||
|
Communication Protocol
|
OCPP 1.6
|
||
|
Connection Communication Mode
|
In accordance with DIN 70121 and ISO 15118 standard
|
||
|
Connection Standard
|
CCS2 (IEC61851-23) and CHAdeMO 1.0
|
||
|
ENVIRONMENT
|
|||
|
Operating Temperature
|
-25°C to 50°C
|
||
|
Humidity
|
0 - 95% (non-condensing)
|
||
|
Altitude
|
< 2000m
|
||
|
Noise Level
|
<65dB
|
||
|
PHYSICAL
|
|||
|
IP Protection
|
IP54
|
||
|
Cable Length
|
5m
|
||
|
Dimension, D x W x H (mm)
|
750 x 530 x 1685, excluding plug and cable
|
||
|
Net Weight (kgs)
|
275
|
310
|
328
|